Posts Tagged :

Rega RB330

How to Measure Turntable Cartridge Azimuth and Crosstalk

1024 576 Michelangelo

When everything looks straight, but the measurements tell another story.

There is something rather satisfying about aligning a cartridge.

You place the protractor on the turntable, carefully lower the stylus onto the grid, look at the cartridge from above, then from the front. Perhaps you use a magnifying glass, or take a photograph with your phone because your eyes are no longer quite as cooperative as they used to be.

You move your head slightly to the left. Then to the right. You find a better light. Perhaps you enlarge the photograph on the screen and draw a line through the cantilever.

A little adjustment here. Another there.

Eventually, the cartridge looks straight, the cantilever appears perfectly aligned, and you convince yourself that everything is as it should be.

Excellent.

But is it?

I have been asking myself this question for some time. Not because I distrust the traditional methods of turntable cartridge alignment. Quite the opposite. They are essential, and I have used them for years.

The problem is that we tend to assume that what looks mechanically correct must also behave correctly when the stylus enters the groove.

And that is not necessarily true.

We can spend an extraordinary amount of time making sure that a cartridge is correctly positioned, that the overhang is accurate, that the tracking force is appropriate and that the tonearm is properly adjusted. All perfectly reasonable things to do.

Yet there is one question that our eyes cannot answer.

What is the cartridge actually doing electrically while the stylus is tracing the groove?

And, perhaps more importantly, how do we know?

Close-up of the Ortofon 2M Bronze mounted on the turntable, with the stylus resting on a record.

The geometry we can see, and the geometry we cannot

Before going any further, we need to understand what we are actually trying to align.

A stereo record contains two channels of information encoded into a single groove. The groove walls are oriented at approximately 45 degrees to the record surface, forming the familiar 90-degree V-shaped groove.

As the stylus follows the groove, its movement is transmitted through the cantilever to the cartridge generator, where that mechanical movement becomes an electrical signal.

Simple enough in principle.

But the stylus is not just a small point resting at the bottom of the groove. It contacts the groove walls through carefully shaped surfaces, and the orientation of those surfaces matters.

One of the parameters involved is called azimuth.

In practical terms, azimuth describes the side-to-side angular orientation of the stylus relative to the groove. Viewed from the front, imagine a line passing through the stylus. Ideally, the stylus contact geometry should be correctly oriented relative to the two groove walls.

Now consider the cartridge itself.

The body may be perfectly horizontal. The cantilever may appear straight. Yet the stylus might not be mounted at precisely the angle we expect.

Manufacturing tolerances exist, even in good cartridges. The stylus, cantilever, suspension and generator are separate elements assembled into a very small mechanical system.

And the cartridge’s electrical generator introduces another consideration: its channel axes may not correspond perfectly to what we see when looking at the cartridge body.

This means that physical alignment, stylus alignment and electrical channel separation are related, but they are not interchangeable.

A perfectly horizontal cartridge body does not guarantee perfect electrical separation.

Equally, the azimuth position that produces the best electrical separation is not automatically proof that the stylus contact surfaces are geometrically ideal.

That distinction is important, especially when deciding how far we should adjust a cartridge.

Front-facing cross-section of a stereo record groove showing the two 45-degree groove walls, the stylus and the left/right channel directions. A second illustration compares correct stylus orientation with a slightly tilted stylus.

When two channels are not quite independent

To understand why azimuth matters, we need to introduce another term: crosstalk.

Ideally, when a record contains information intended only for the left channel, the cartridge should reproduce that information exclusively through its left output.

In reality, some of the signal appears in the opposite channel.

That unwanted contribution is called crosstalk.

The same happens in the other direction.

If we play a signal recorded only in the left channel, we can measure how much appears in the right. We call this L→R crosstalk.

Then we repeat the test with a signal recorded only in the right channel and measure the leakage into the left: R→L.

The result is usually expressed in decibels relative to the signal in the intended channel.

For example, a crosstalk value of −30 dB means that the unwanted signal has a voltage amplitude approximately 31.6 times smaller than the wanted signal, assuming comparable measurement conditions.

The more negative the value, the better the separation.

Manufacturers often express the same concept as positive channel separation. Thus, −30 dB crosstalk corresponds to 30 dB separation.

So far, nothing particularly mysterious.

But there is a detail that is often overlooked.

The two directions do not necessarily produce the same result.

We might measure −30 dB from left to right and only −25 dB from right to left.

Why?

Several factors may contribute, including generator geometry, mechanical alignment, differences in the recorded test signals and the measurement chain.

A difference does not automatically prove that the stylus is tilted. But it tells us that the complete playback system is not behaving identically in both directions.

And that is useful information.

It also introduces a question that becomes central to our experiment.

Should we adjust azimuth to maximise channel separation, or should we try to make the two directions as similar as possible?

Perhaps the answer is neither.

Or, more precisely, perhaps we need to consider both.

Two simplified signal paths. First, a left-only 1 kHz signal with a strong left-channel waveform and a much smaller right-channel waveform. Second, the reverse. Label L→R and R→L clearly.

From looking to measuring

For this experiment, I used an Ortofon 2M Bronze cartridge and a test record containing the necessary 1 kHz channel signals.

The electrical output was captured through an Audient EVO4 audio interface and analysed using Groove Scope.

The principle is straightforward.

We reproduce a known signal, capture the electrical output and compare the amplitude of the intended channel with the amplitude appearing in the opposite channel.

We then repeat the procedure in the other direction.

What matters is that the measurements are taken under comparable conditions. We want to investigate the cartridge, not changes introduced by different gain settings, routing or measurement procedures.

Groove Scope gives us the two crosstalk measurements, their difference, average separation and additional diagnostic information.

This is useful because it allows us to evaluate the complete result rather than chasing a single number.

And the first measurement gave me something worth investigating.

The first surprise

The initial results were:

Measurement Initial result
L→R crosstalk −29.0 dB
R→L crosstalk −24.6 dB
Crosstalk imbalance 4.32 dB
Average separation 26.8 dB
Left/right output balance +0.25 dB

At first glance, these are not disastrous figures. We are still talking about a cartridge providing useful stereo separation.

But look more closely.

One direction is performing substantially better than the other.

The left-to-right result is reasonably strong, while the right-to-left result is noticeably weaker.

And here comes another interesting detail.

The measured output-level balance between left and right was only +0.25 dB.

So the cartridge was delivering very similar output levels from the two channels, despite the difference in their electrical separation.

This is a useful reminder that channel balance and channel separation are not the same thing.

A cartridge can have excellent left/right output balance while showing a significant difference in crosstalk.

If we relied only on the relative loudness of the two channels, we might never notice the separation asymmetry.

The measurement had revealed something that was not obvious from the visual alignment or the channel levels.

But what should we do with that information?

Initial Groove Scope diagnostic showing 4.32 dB more leakage into the left channel, before the azimuth adjustment.

A small adjustment, a rather different result

The next step was to investigate whether changing the cartridge’s azimuth could improve the measured behaviour.

This is where I believe measurement becomes genuinely valuable.

Without an instrument, we might make a tiny adjustment, listen to a familiar record and try to decide whether something has changed.

Perhaps it sounds better. Perhaps not.

The difficulty is that small differences are notoriously difficult to evaluate reliably when we are also expecting to hear an improvement.

With a measurement, we can at least establish whether the electrical behaviour has changed in a direction we consider beneficial.

After adjusting the cartridge’s azimuth, I repeated the test.

The second results were:

Measurement Before After
L→R crosstalk −29.0 dB −31.3 dB
R→L crosstalk −24.6 dB −31.5 dB
Crosstalk imbalance 4.32 dB 0.24 dB
Average separation 26.8 dB 31.4 dB
Left/right output balance +0.25 dB +0.16 dB

Now this was interesting.

The original 4.32 dB imbalance had almost disappeared.

But even more importantly, both directions had improved.

The L→R result improved by 2.3 dB.

The R→L result improved by 6.9 dB.

Average separation increased by 4.6 dB.

That is not simply a matter of exchanging performance in one channel for performance in the other.

The measured electrical separation improved overall, and the two directions became much more closely matched.

In other words, the new setting produced a better electrical result according to both criteria.

This is exactly the kind of result that makes an experiment satisfying.

We began with a question, made an adjustment, repeated the measurement and obtained a clear difference.

The cartridge had given us an answer.

Second Groove Scope diagnostic showing 0.24 dB crosstalk imbalance and the close match between the two channels.

Comparison chart showing L→R and R→L separation before and after the adjustment, with average separation increasing from 26.8 dB to 31.4 dB. Use positive separation values for clarity.

Why the best number is not always the best adjustment

At this point, it would be tempting to conclude that we simply need to adjust every cartridge until both crosstalk measurements are identical.

Unfortunately, things are rarely quite so convenient.

Imagine that we adjust a cartridge and obtain −35 dB in one direction but only −22 dB in the other.

We have achieved an excellent result for one channel, but at the expense of the other.

Now imagine another setting that gives us −30 dB in both directions.

Which is better?

For practical electrical separation, the second result may well be preferable, because neither channel is being significantly compromised.

But we must also remember that electrical separation is not a direct measurement of the stylus contact geometry.

The cartridge generator, the stylus assembly and the groove form a complex mechanical and electrical system.

It is possible to obtain a very attractive crosstalk balance at an azimuth setting that is not geometrically ideal for the stylus.

This is particularly relevant with more sophisticated stylus profiles, where the orientation of the contact surfaces matters.

So I would not recommend using crosstalk as an excuse to tilt a cartridge excessively.

Visual alignment remains an important starting point.

The aim is to find a sensible practical setting that respects the mechanical geometry while achieving good, repeatable electrical performance.

And in our experiment, the encouraging observation was that the improved crosstalk balance came together with better separation in both directions.

That is a considerably more persuasive result than balance alone.

There was another change hiding in the measurements

So far, we have concentrated on channel separation.

But Groove Scope also captured harmonic distortion information during the experiment.

And here we find another interesting observation.

In the initial measurement, total harmonic distortion was 0.81% on the left and 0.85% on the right.

After the adjustment, it was 0.78% and 0.83% respectively.

These are small changes in absolute percentage terms.

However, the direction of the change is worth noticing.

Both channels showed slightly lower measured distortion after the adjustment.

Now, a single pair of measurements would not be enough to establish a general rule about azimuth and harmonic distortion.

But the Rotation Fingerprint comparison adds another perspective.

Rather than relying only on one aggregate result, it examines the behaviour across consecutive platter rotations and produces median profiles.

In that comparison, the left-reference median THD remained essentially unchanged at 0.79%.

The right-reference median moved from 0.88% before the adjustment to 0.82% afterwards.

This is particularly interesting because the right-reference measurement was also the direction in which the crosstalk performance had been weaker before the adjustment.

We now have two observations associated with the changed setup: substantially improved electrical separation and a lower right-reference median distortion result.

The evidence is not sufficient to prove that azimuth alone caused the distortion change. Groove Scope itself identifies limitations in the strength of that comparison.

Nevertheless, I would not dismiss it.

It is a measurable difference that occurred alongside the azimuth adjustment, and it provides a good reason to investigate further.

Sometimes the value of a measurement is not that it gives us a definitive answer.

Sometimes it tells us where to look next.

[IMAGE 07 — THD FINGERPRINT COMPARISON, LEFT REFERENCE]

Before-and-after median THD profile for the left reference. The median remains approximately 0.79% in both measurements.

[IMAGE 08 — THD FINGERPRINT COMPARISON, RIGHT REFERENCE]

Before-and-after median THD profile for the right reference. The median decreases from 0.88% to 0.82% after the adjustment.

What happens during one revolution?

There is another reason I find the Rotation Fingerprint analysis fascinating.

A conventional measurement often gives us one value that summarises what happened during the test.

That is useful, but it can conceal variations occurring over time.

A vinyl record is not a perfectly abstract signal source.

It is a physical object rotating beneath a mechanical pickup system. The stylus is continuously responding to the groove, while the cartridge, tonearm and record form part of the playback process.

Groove Scope’s Rotation Fingerprint presents measurements across successive platter revolutions.

Each row represents a rotation, while the horizontal axis follows the relative angular position around the record.

By comparing the rows, we can observe whether certain behaviours appear consistently at similar positions.

In the supplied leakage fingerprints, the patterns are visibly different between captures and between reference channels.

Some show more pronounced regions of variation. Others appear considerably more uniform.

It is important not to interpret every variation as a cartridge problem.

A recurring feature might be associated with the record, its groove modulation, pressing characteristics or other aspects of playback.

The fingerprint does not automatically tell us the cause.

But it gives us something that a single number cannot: a view of how the measurement behaves over successive revolutions.

And that opens an entirely new area of investigation.

If we observe a difference between two azimuth settings, is the change consistent throughout the rotation?

Does one channel behave differently at particular angular positions?

Are the results repeatable if we play the same passage again?

These are questions that deserve their own experiment.

For now, the important point is that the average crosstalk result and the rotation-dependent behaviour describe different aspects of the same playback system.

We should not confuse them.

[IMAGE 09 — ROTATION FINGERPRINT BEFORE ADJUSTMENT]

Leakage fingerprint from the initial measurement, preferably showing the right-reference pattern.

[IMAGE 10 — ROTATION FINGERPRINT AFTER ADJUSTMENT]

Corresponding leakage fingerprint from the second measurement. Place the two images side by side if the Journal layout allows it.

And then, finally, the music

Of course, there is a reason why we spend so much time adjusting turntables.

It is not because we particularly enjoy looking at numbers on a screen.

Well, perhaps some of us do.

But ultimately, the objective is to listen to music.

After completing the adjustment, I returned to familiar records.

The same cartridge. The same turntable. The same system.

And the presentation had changed.

There was a greater sense of air around the instruments, a more clearly defined stereo image and a soundstage that seemed to open up beyond what I had experienced before.

The instruments occupied their own positions more convincingly. The presentation felt more spacious, with a greater sense of separation and ease.

These are listening impressions, of course, not measurements.

I cannot take a 4.6 dB improvement in average electrical separation and translate it directly into a specific improvement in perceived soundstage width.

Nor can I claim that the small measured change in harmonic distortion explains everything I heard.

Listening is more complicated than that.

But I find the sequence of events compelling.

I began with a cartridge that appeared correctly aligned.

The initial measurement revealed unequal crosstalk.

I changed the azimuth and repeated the experiment.

Both directions of electrical separation improved, the crosstalk imbalance almost disappeared, and the distortion measurements provided some additional encouraging observations.

Then I listened.

And I preferred the result.

That does not turn a listening impression into a laboratory proof. But it does give the experiment a satisfying conclusion.

The measurements guided the adjustment. The listening experience gave it meaning.

The turntable playing a record in the actual listening environment. A warm, personal photograph that moves the article away from graphs and back to music.

When straight is not necessarily right

So what did we learn?

First, that visual cartridge alignment remains essential, but cannot tell us everything about electrical performance.

Second, that left/right output balance and channel separation are different measurements. A cartridge can reproduce both channels at almost identical levels while allowing considerably more information to leak from one channel into the other.

And third, perhaps the most interesting discovery of all, that a very small azimuth adjustment can produce a rather

Resonance ab

Once Upon a Time, There Was the Rega Planar: The Resonance Hidden Beneath the Music

1024 639 Michelangelo

A turntable does not operate in isolation. Tonearm mass, cartridge compliance, mounting hardware, furniture, floors and walls all participate in the result. Resonance Lab was created to make those relationships visible—before uncertain listening impressions become unnecessary purchases or endless adjustments.

Once upon a time, there was Rega.

Not Rega as an object of endless forum debate. Not Rega as a flag to be waved in the eternal arguments between belt drive and direct drive, low mass and high mass, suspended designs and rigid plinths.

Rega as an idea.

A simple, almost stubborn idea: remove what is unnecessary, make rigid what must remain still and avoid allowing unwanted energy to accumulate within the structure.

Perhaps that is why a Rega Planar 3 can still appear both modern and slightly old-fashioned. Modern because it is visually restrained, mechanically purposeful and free from excessive mass. Old-fashioned because it recalls a period of British hi-fi in which products often appeared to have been designed to solve practical problems rather than to resemble industrial monuments.

These were not domestic altars constructed from huge slabs of metal and acrylic. They were comparatively light, intelligent instruments intended to operate in real homes.

And this is where the story becomes interesting.

Lightness Is a Design Decision

The Rega Planar 3 is simple, but it is not simplistic.

Rega describes the Planar 3 as using a lightweight laminated plinth reinforced between the tonearm mounting and main bearing by its double-brace structure. The intention is to increase rigidity where it is required without turning the complete plinth into a large energy-storing mass.

This philosophy differs from the approach of a turntable that attempts to resist vibration primarily through weight.

A low-mass, high-rigidity design aims to minimise stored energy and reduce the duration of unwanted resonances within the structure. Rather than trying to become an immovable object, it attempts to manage energy quickly and predictably.

But every engineering philosophy creates conditions under which it performs best.

A lightweight turntable may respond differently to its support and surrounding structure than a very heavy, highly damped design. The equipment table, floor and wall are not automatically external to the turntable system. Under some conditions, they become part of it.

A Rega must therefore be given the right environment in which to behave like a Rega.

That does not always happen.

A Planar 3 on a Suspended Wooden Floor

The system in this case consisted of a modern Rega Planar 3 with its RB330 tonearm and an Audio-Technica AT-OC9XML moving-coil cartridge.

It was an interesting combination. The Microlinear stylus and boron cantilever of the AT-OC9XML offered excellent tracking potential, while the RB330 provided the rigid, low-friction platform around which the Planar 3 had been designed.

The turntable was positioned on a good-quality equipment table.

The table, however, stood on the suspended wooden floor of an English house.

The result was good, but not memorable.

It was controlled, detailed and pleasant, yet it did not quite deliver the immediacy, rhythm and physical presence often associated with a well-installed Rega.

The bass was present but did not feel completely secure. The soundstage opened, but it did not always seem to lock firmly into place. Voices were clear, yet the central image lacked some of the natural solidity that can transform competent reproduction into a convincing musical event.

None of this amounted to an obvious malfunction.

The stylus did not jump. There was no dramatic feedback, no clearly audible mechanical noise and no single defect that could be isolated immediately.

The system simply appeared to play with a small hesitation hidden beneath the music.

The Traditional Audiophile Response

The first instinct in situations like this is often to begin changing things.

We change the interconnect. We try another platter mat. We suspect the cartridge. We adjust tracking force, vertical tracking angle, azimuth and anti-skating. Eventually, we spend an afternoon staring at the tonearm as though it were about to confess.

Audiophiles know this ritual well.

When something does not sound quite right, the mind generates possible explanations faster than they can be tested. Some are technically reasonable. Others are elegant methods of converting uncertainty into maintenance.

Before changing anything, however, it is worth asking a simpler question:

What is the expected mechanical behaviour of the tonearm and cartridge combination?

The Tonearm and Cartridge Resonance

A cartridge suspension behaves like a spring, while the effective moving mass of the tonearm, cartridge and mounting hardware behaves like a mass attached to that spring.

Together they form a resonant mechanical system.

The commonly used estimate is:

fr = 159 / √(M × C)

where:

  • fr is the estimated resonance frequency in hertz;
  • M is the total moving mass in grams;
  • C is the cartridge’s dynamic compliance around the resonance region, expressed in µm/mN or an equivalent compliance unit.

For this system, the published and estimated inputs were:

  • RB330 effective mass: 11 g;
  • AT-OC9XML cartridge mass: 7.6 g;
  • mounting screws and washers: approximately 1–1.5 g.

This produces a total moving mass of approximately 19.6–20.1 g.

The Compliance Problem

The next figure is less straightforward.

Audio-Technica specifies the AT-OC9XML’s dynamic compliance as 16 × 10⁻⁶ cm/dyne at 100 Hz.

Tonearm and cartridge resonance, however, normally occurs much lower, generally somewhere around the single-digit or low-double-digit hertz region. A compliance value measured at 100 Hz cannot simply be inserted into the formula as though it described the suspension identically at 10 Hz.

Compliance is frequency-dependent, and manufacturers do not all publish it under the same test conditions.

Enthusiasts and designers therefore sometimes apply a practical conversion multiplier to Japanese 100 Hz specifications. Values between approximately 1.5 and 2 are commonly explored, but this is a heuristic—not a universal physical conversion law.

Using a factor of 1.7 gives an estimated 10 Hz compliance of:

16 × 1.7 = 27.2 µm/mN

Entering that estimate into the resonance formula gives:

159 / √(19.6 × 27.2) ≈ 6.9 Hz

With the slightly greater mass estimate of 20.1 g, the result becomes approximately:

159 / √(20.1 × 27.2) ≈ 6.8 Hz

The calculation therefore suggests a resonance around 6.8–6.9 Hz under that particular compliance assumption.

But the decimal places must not seduce us into believing that the estimate is more precise than the input data.

If different plausible conversion assumptions are explored, the predicted resonance can move approximately between 6.3 and 7.3 Hz. The real cartridge suspension may also differ from the nominal specification, and mounting conditions can affect the result.

The honest conclusion is therefore not:

“This combination resonates at exactly 6.86 Hz.”

It is:

“This combination is likely to operate near the lower end of the generally preferred resonance region and deserves closer attention.”

What a Low Estimate Actually Means

A predicted resonance below the centre of the preferred range does not automatically mean that the tonearm and cartridge are unusable together.

Ortofon currently describes approximately 7–12 Hz as an optimal region, with 10 Hz as a useful target. It also notes that values around 6.5–7 Hz may still be usable without problems.

This makes the distinction between a warning and a verdict extremely important.

A result near 6.8 or 6.9 Hz does not say:

“Remove this cartridge immediately.”

It says:

  • the combination may be more sensitive to record warps;
  • subsonic energy deserves attention;
  • the turntable support may become particularly important;
  • structural movement should not be dismissed;
  • and calculated behaviour should ideally be checked against observation or measurement.

The system was not necessarily wrong.

It was potentially delicate.

Where Resonance Lab Becomes Useful

This is the purpose of Resonance Lab.

It does not replace listening, and it does not convert analogue reproduction into a simple pass-or-fail calculation.

It provides a structured way to examine the relationship between tonearm effective mass, cartridge weight, mounting hardware and compliance.

Most importantly, it allows the user to see how assumptions change the result.

In a case such as the AT-OC9XML, the compliance conversion should not be hidden behind an apparently unquestionable number. It should be explored.

What happens if the effective compliance is closer to 24 µm/mN?

What happens if it is closer to 27 or 32?

What is the effect of an additional gram of mounting mass?

Would a lighter cartridge move the resonance significantly?

Does the result remain comfortably inside the desired region, or is it strongly dependent on uncertain inputs?

This is more informative than asking whether two products are merely “compatible.”

Compatibility is rarely binary.

A combination may be:

  • comfortably matched;
  • technically usable but sensitive to its environment;
  • dependent on uncertain compliance data;
  • or sufficiently extreme to justify reconsideration.

Resonance Lab makes that uncertainty visible.

What Resonance Lab Does Not Do

A calculation cannot measure a moving floor.

It cannot determine the actual structural resonance of an equipment rack, quantify footfall vibration or prove that a wall shelf will improve every system.

It also cannot know the exact low-frequency compliance of an individual cartridge unless that value has been measured under relevant conditions.

Resonance Lab therefore does not diagnose environmental vibration directly.

Its role is different: it helps identify whether the arm and cartridge combination makes environmental vibration a plausible and technically consistent part of the investigation.

In this case, it did not prove that the wooden floor was responsible.

It made the floor impossible to ignore.

The Floor Enters the System

Suspended wooden floors are elastic structures.

They move under footsteps and distribute low-frequency mechanical energy through joists, boards, furniture and equipment supports. The degree of movement depends on the building, span, construction, loading and position within the room.

This is not automatically a defect. It is simply the behaviour of the structure.

Anyone who has lived in an older English house knows that the building cannot be understood only by looking at it. It creaks, moves, breathes and responds.

An analogue turntable responds too.

When a tonearm and cartridge system is already operating near a relatively low resonance frequency, low-frequency structural movement may become more relevant. The interaction need not be dramatic enough to throw the stylus from the groove.

It may instead appear as:

  • less articulate bass;
  • a centre image that does not feel completely settled;
  • reduced rhythmic certainty;
  • slightly unstable spatial focus;
  • or a vague sense that the performance is not firmly grounded.

These descriptions are subjective listening observations, not unique diagnostic signatures. Similar impressions can have many causes.

But when the calculated arm and cartridge behaviour points towards greater low-frequency sensitivity, the support structure becomes a rational variable to test before purchasing new components.

The Load-Bearing Wall

The turntable was moved from the equipment table to a high-quality wall shelf fixed to a solid load-bearing wall.

The listening change was substantial.

The bass did not simply become more abundant. It became easier to follow. Low notes felt less hesitant and more clearly connected to the musical line.

Transient definition improved. The soundstage became more stable. Voices gained a firmer centre, and instruments occupied more credible positions.

Most importantly, the reproduction acquired a stronger sense of continuity.

The music no longer seemed to pass through a succession of small, invisible obstacles.

It flowed.

This observation does not establish a controlled scientific comparison, and it does not prove that every Rega turntable should be wall-mounted.

It does, however, align with Rega’s own approach. The company produces a lightweight, rigid wall bracket specifically for the Planar 1, Planar 2, Planar 3 and Planar 6, describing it as a vibration-isolation solution intended to complement its lightweight turntables.

The shelf did not add musical information.

Good mechanical engineering rarely adds magic.

It removes interference.

A Case Study, Not a Universal Rule

Not every wooden floor is unsuitable for a turntable.

Not every equipment table performs poorly.

Not every Rega must be placed on a wall shelf, and not every wall is structurally appropriate for supporting one.

A concrete floor and a stable rack may provide excellent conditions. A poorly installed wall shelf may create its own problems. A different tonearm and cartridge combination may be less sensitive to low-frequency movement.

The purpose of this case is not to produce another audiophile commandment.

It is to demonstrate a better sequence of reasoning:

  1. Describe the listening problem without immediately deciding its cause.
  2. Check the published mechanical specifications.
  3. Model the tonearm and cartridge resonance.
  4. Identify uncertainty in the compliance data.
  5. Explore plausible scenarios rather than trusting one exact number.
  6. Consider the support and building structure.
  7. Change one meaningful variable.
  8. Listen again—and measure where possible.

This is far more useful than changing three accessories simultaneously and then attempting to remember which one supposedly transformed the system.

Why I Created Resonance Lab

Tonearm and cartridge resonance has remained unnecessarily mysterious for too long.

The subject often sits somewhere between textbook equations, manufacturer specifications expressed under different conditions, enthusiast-produced compatibility charts and forum discussions in which every confident statement is followed by another confident statement claiming the opposite.

Resonance should not be an initiation ritual.

It should not be reserved for people who enjoy calculations more than music.

It should be a practical tool for better decisions.

I created Resonance Lab to make the relationship understandable and explorable.

The app does not tell the user what to hear. It helps organise the variables that may explain what they are hearing.

It can help reveal whether a combination is:

  • comfortably within a preferred region;
  • near a boundary;
  • highly dependent on an uncertain compliance conversion;
  • or potentially sensitive to environmental conditions.

It can also help prevent expensive misdiagnoses.

A new cartridge will not solve a moving floor if the replacement produces the same mechanical relationship. A different mat will not correct an unsuitable arm and cartridge match. A heavier mounting plate may move the resonance in the wrong direction.

Sometimes the most important upgrade is not another component.

It is a clearer understanding of the system already in front of us.

From Calculation to Reality

The calculated resonance frequency is a starting point, not the final truth.

Where possible, it should be complemented by real-world observation or measurement using a suitable test record and analysis method.

A measured result can reveal the actual resonance peak of the installed system, including the behaviour of the individual cartridge suspension rather than only its nominal specification.

Calculation and measurement serve different purposes:

  • calculation helps evaluate combinations before purchase and explore alternatives;
  • measurement reveals how the installed system actually behaves;
  • listening tells us whether that behaviour is musically significant in the complete system.

None should be forced to perform the role of the others.

The strongest diagnosis emerges when all three point in the same direction.

Understanding Rega Without Worshipping It

Understanding this case does not require worshipping Rega as a brand.

It requires understanding why its design choices make sense.

A Rega is not “simple” in the impoverished sense of the word. It follows a specific path based on lightness, rigidity and controlled energy behaviour.

But a specific design philosophy also requires a suitable context.

Place the turntable on a structure that moves, and under certain conditions it may tell you.

Give it a stable mechanical reference, and it may stop defending itself and begin to communicate the music more freely.

Perhaps this is one reason Rega has retained such a distinctive identity. When the system is working well, the turntable does not seem to be trying to impress the listener.

It simply allows the performance to pass through.

The Relationship Beneath the Music

A turntable is not a collection of isolated products.

The tonearm, cartridge, compliance, mounting screws, support, floor, walls and furniture all participate in its mechanical behaviour.

Sometimes their influence is obvious.

At other times, it does not add a recognisable defect. It removes certainty.

That is the deeper purpose of Resonance Lab.

It does not replace the ears, and it does not promise to solve every analogue problem through a formula.

It makes relationships visible.

In this case, the app showed that the RB330 and AT-OC9XML combination was not absurd, but potentially sensitive. That made the suspended floor a credible variable rather than a piece of inherited audiophile folklore.

The wall shelf then became more than an accessory recommended by tradition.

It became a mechanical response to a specific hypothesis.

Once upon a time, there was Rega.

But Rega is still here.

To hear it properly, we may simply need to understand where it came from, what it is trying to achieve and the environment in which we are asking it to perform.

Because in analogue reproduction, sound never comes from one component alone.

It comes from a relationship.

And sometimes, to rediscover the music, we do not need to replace the turntable.

We simply need to remove the floor from the conversation.

Explore Resonance Lab

Resonance Lab helps vinyl enthusiasts explore tonearm and cartridge compatibility, estimate system resonance and compare how changes in mass or compliance may influence the result.


Learn more about Resonance Lab


Download Resonance Lab from the App Store

References and Technical Sources

  1. Rega Research. “Planar 3.”

    View official product information
  2. Rega Research. “RB330 Tonearm.”

    View official specifications
  3. Audio-Technica. “AT-OC9XML Dual Moving-Coil Stereo Cartridge.”

    View official specifications
  4. Ortofon. “Matching Cartridges with Tonearms.”

    View resonance formula and guidance
  5. Rega Research. “Turntable Wall Bracket.”

    View official product information

This article describes a real-world setup and subjective listening observations supported by resonance modelling. Calculated resonance values are estimates and depend on the accuracy and measurement frequency of the compliance data. They should not be interpreted as a substitute for direct measurement of the installed system.